Document Type
Article
Publication Date
7-16-2025
Publication Title
Journal of Medical Devices
Abstract
Bubble continuous positive airway pressure (bCPAP) is a minimally invasive respiratory support for neonates experiencing respiratory distress syndrome (RDS). It exerts continuous, oscillatory air pressure to encourage lung function and development. Neonates’ movement may cause disconnections at the nasal interface. These disconnections are characterized by the cessation of bubbling at the bCPAP respiratory circuit output and frequently go unnoticed until hypoxia develops. Common Neonatal Intensive Care Unit (NICU) bCPAP systems lack a built-in alarm or accessory device to monitor for disconnections. As a result, nursing personnel must exercise extreme caution utilizing current bCPAP procedure. If a neonate is disconnected, it may go unnoticed for 4 h or more, depending on nurse availability and rounding schedules. To solve this issue, we propose a novel vibration-based detection apparatus to augment existing bCPAP systems that immediately alert clinicians on the cessation of bubbling in the bCPAP water canister. Our independent monitoring system can assure staff that neonates will not develop hypoxia-related complications due to bCPAP failure. Preliminary benchtop testing with a model bCPAP system indicates that the monitor is effective in detecting bubbling cessation under simulated bCPAP operation conditions, in the pressure range of 5–10 cmH2O. The monitor detected disconnections in an average of 4.22 s across all setting trials, minimizing the time to intervention. While this study was limited to benchtop testing, our initial findings indicate that an accessory bubbling monitor allows for early detection of bCPAP disconnections with future utility in the NICU.
Volume
19
Issue
4
Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License.
Recommended Citation
Calabresi, Kaitlyn G.; Bhat, Meera R.; Kong, Lavinia L.; Foster, Eli J.; Wang, Jonathan; Koilada, Sangeeta; Mak, Angela; Kapadia, Aastha; Mohseni, Niam; Leung, W. Keith; Desiraju, Suneetha; and Miranda, Constanza, "Vibration-Based Detection for the Monitoring of Neonatal bCPAP Respiratory Support to Minimize Duration of Disconnections" (2025). School of Medicine Faculty Publications. 4071.
https://digitalscholar.lsuhsc.edu/som_facpubs/4071
10.1115/1.4068970
Included in
Biomedical Devices and Instrumentation Commons, Pediatrics Commons, Respiratory System Commons, Therapeutics Commons